28-6-2011 29 033000=13069F
10.2 Installing an extra siren
10.2.1 PH7208
Set the siren PH7208 to address A1 or A2 (=HC, UC=1 or 2). To avoid false alarms, the system
waits 20 seconds after triggering the alarm before the siren is activated. The siren will give a
strident two-tone signal for 4 minutes. After these 4 minutes the siren is automatically switched
off (or sooner if the alarm is switched off).
ATTENTION: When using a security system, the extra sirens will always work in case of an alarm,
even when the system is set to silent alarm! The Siren PH7208 is meant for indoor use and can be
plugged into any wall socket (230V/50Hz).
10.2.2 SH10 Security Horn / Remote Chime
Set the siren SH10 to address B5 (=HC+1, UC=5). ATTENTION: When using a security system, the
extra sirens will always work in case of an alarm, even when the system is set to silent alarm! The
Siren SH10 is meant for indoor use and can be plugged into any wall socket (230V/50Hz).
If Chime is enabled, opening a D/W sensor gives a pleasant 6 tone message. It also gives tones
for Exit Delay when Arming, one single tone once every 4 seconds.
10.3 Using an external universal siren
You can also add sirens and flash lights that are not part of the (current) range. Please use a
separately available AD10, AW12 or AM12 Appliance Module. Set this module to address B6
(=HC+1, UC=6). The module is switched on in case of an alarm and switched off after 4 minutes.
10.4 Transceiver function
The X10 product range contains several wireless remote controls that you can use to control
your X10 modules (such as a universal remote control for your TV, audio equipment and X10).
These remote controls use radio signals, which means the remote control signal goes through
walls and ceilings. See www.bmbelectronics.eu
for more information. Your console will convert
these remote control RF signals to X10 signals and transmit them via the power lines. You can
then control the X10 modules using these transmitters.
10.5 All Home Automation functions at a glance
Name Description Module set to address
Comfort lighting You can switch your lighting using the A1 and A2
buttons Lights ON and Lights OFF on (=HC, UC=1 + UC=2)
your key chain remote control.
Exit delay Lights are switched on during the exit delay. A1 and A2 (=HC, UC=1 + UC=2)
Alarm lighting In the case of an alarm, the lights will flash A1 and A2
during 4 minutes and then remain on. (=HC, UC=1 + UC=2)
Status indicator The lights are switched on when the system B4 (=HC+1, UC=4)
is set to ARM AWAY.
Extra Siren PH7208 Extra 110dB siren. A1 or A2(=HC, UC=1 + UC=2)
Extra Siren SH10 Remote Chime. B5 (=HC+1, UC=5)
Universal Siren Connect an own siren to a AM12 or B6 (=HC+1, UC=6)
AD10 module.
H.A. Automation H.A. functions in respond to sensor (27-32) B7 – B12
when in ARMED mode and triggered. (=HC+1, UC=7-12).
Thermostats Thermostat H.A. addresses. B13 – B16 (=HC+1, UC=13-16).
*This table uses the unchanged settings (House Code + Unit Code) for the basic console address.
The default base address is A1.